See AllS2000 14L5 Ultrasound Linear Probe Transducer Sonar Scan
Medical Ultrasound Scanner Probe Siemens S2000 14L5 Linear Parts Transducer Sonar Scan
Siemens 14L5 Linear Small Parts Transducer
1.Type: linear
2. Frequency: 14-5MHz
3. Compatible system: S2000
4. Application: Small Parts
5. Condition: pre-owned and original, in good working condition
6. With 60 days warranty
Knowledge point
Applications of Elastography
Elastography is used for the investigation of many disease conditions in many organs. It can be used for additional diagnostic information compared to a mere anatomical image, and it can be used to guide biopsies or, increasingly, replace them entirely. Biopsies are invasive and painful, presenting a risk of hemorrhage or infection, whereas elastography is completely noninvasive.
Elastography is used to investigate disease in the liver. Liver stiffness is usually indicative of fibrosis or steatosis (fatty liver disease), which are in turn indicative of numerous disease conditions, including cirrhosis and hepatitis. Elastography is particularly advantageous in this case because when fibrosis is diffuse (spread around in clumps rather than continuous scarring) , a biopsy can easily miss sampling the diseased tissue, which results in a false negative misdiagnosis.
Naturally, elastography sees use for organs and diseases where manual palpation was already widespread. Elastography is used for detection and diagnosis of breast, thyroid, and prostate cancers. Certain types of elastography are also suitable for musculoskeletal imaging, and they can determine the mechanical properties and state of muscles and tendons.
Because elastography does not have the same limitations as manual palpation, it is being investigated in some areas for which there is no history of diagnosis with manual palpation. For example, magnetic resonance elastography is capable of assessing the stiffness of the brain, and there is a growing body of scientific literature on elastography in healthy and diseased brains.
Preliminary reports on elastography used on transplanted kidneys to evaluate cortical fibrosis have been published showing promising results.
Other Siemens probes we can offer:
Brand | Model | Compatible System |
Siemens | 3.5C55S | G50/X150/X300 |
Siemens | 6C1HD | S2000 |
Siemens | 7.5L40A | G20/G40 |
Siemens | 7.5L75S | G20 and Prima / Adara |
Siemens | C7F2 | Antares/ X300 and X500 |
Siemens | CH4-1 | Antares |
Siemens | CH5-2 | G40/G60/X150/X300 |
Siemens | CH6-2 | Antares |
Siemens | CX5-2 | Antares/ Sonoline Elegra |
Siemens | C6-2 | CV70/ G50/G60/ X300/X500 |
Siemens | C6F3 | G50/G60 |
Siemens | C5F1 | Antares |
Siemens | C8-5 | X300 |
Siemens | P10-4 | Antares |
Siemens | PH4-1 | Antares |
Siemens | P4-2 | G50/G60/CV70/X150/X300/X500 |
Siemens | P5-1 | X300, X300PE |
Siemens | EC9-4 | G40/ X150/ X300/Antares |
Siemens | EV9F4 | X300 and Antares |
Siemens | VFX9-4 | Antares |
Siemens | VF13-5sp | Antares/X300/X500/G50/G60 |
Siemens | VFX13-5 | Antares |
Siemens | VF13-5 | X150/X300/X500/G40 /G50/G60/ Sonoline Sienna/Sonoline Elegra |
Siemens | VF13-5 | Antares |
Siemens | VF10-5 | Antares |
Siemens | 4V1C | Sequoia 512 GI, Sequoia C512, S2000 |
Siemens/Acuson | 4V1 | Sequoia |
Siemens/Acuson | 6L3 | Acuson Sequoia |
Siemens/Acuson | 8C4 | Sequoia 512 G /Sequoia C512 |
Siemens/Acuson | 8L5 | Sequoia 512 |
Siemens/Acuson | 8V5 | Sequoia |
Siemens/Acuson | 7L3 | Cypress |
Siemens/Acuson | 8V3 | Sequoia 512 /S1000 |
Siemens/Acuson | 9EVF4 | S1000/ S2000 and S3000 |
Siemens/Acuson | 9L4 | Acuson S2000/ Sequoia/Sequoia C512 |
Siemens/Acuson | 10V4 | Sequoia |
Siemens/Acuson | 15L8W | Sequoia 512 |
Siemens/Acuson | 15L8 | Sequoia |
Siemens/Acuson | 17L5HD | Sequoia 512 |
Siemens/Acuson | 18L6HD | S1000, S2000, S3000 |
Siemens/Acuson | AUX CW | Cypress / Cypress CV System |
Siemens/Acuson | C3 | Aspen |
Siemens/Acuson | EC9-4 | G40/ G60/X150/ X300 |
Siemens/Acuson | EC7 | Aspen/ XP128 |
Siemens/Acuson | EV-8C4 | Sequoia 512/ S2000 |
Siemens/Acuson | EC-10C5 | Sequoia 512 |
Siemens/Acuson | L5 | Aspen |
Siemens/Acuson | L7 | Aspen/128XP-10 |
Siemens/Acuson | TE-V5M | Sequoia/ Sequoia C512/Sequoia 512/ Aspen/ Cypress/S1000/S2000 |
Siemens/Acuson | TE-V5Ms | Cypress/Sequoia/S2000/X300 systems |
Siemens/Acuson | V4 | Aspen/ XP |
Siemens/Acuson | V7 | Aspen/ XP |
Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)
Common ultrasonic probe damage | Solutions |
Lens damage, wear, holes, swelling, delamination | Lens replacement |
Strain relief damage, separation | Strain replacement |
Nosepiece and probe separation and cracks | Strain replacement |
Cable cuts | Cable patches, possible cable replacement |
Connector housing electrical damage | Major and minor electrical repairs, pin module replacement |